Elevator use management and maintenance rules
To enable the use of elevators in the management and maintenance of the formation of a unified, can meet the basic requirements of elevator safety guarantee and the normal operation of the, to achieve the elevator code using the purpose of management and maintenance work, the State General Administration of quality supervision, inspection and Quarantine on May 8, 2009 approved promulgated the "elevator usage management and maintenance rules (TSG T5001-2009)", since August 1, 2009 implementation. Part of the new rules are published as follows, for the reader to learn the reference.
Chapter one is the first chapter
Article 1 in order to regulate the use of the elevator management and maintenance activities, according to the "special equipment safety supervision regulations", the development of this rule.
These rules apply to the management and maintenance of elevators in the application scope of the "special equipment safety supervision regulations" second.
This rule does not apply to an individual or a single home for personal use.
Article 3 the rules is to use the elevator management and daily maintenance (hereinafter referred to as the Vyborg) basic requirements, relevant units according to the development of science and technology and the actual situation can develop than the rules of work requirements, to ensure the elevator maintenance safety performance.
The second chapter uses the management
Fourth units should be used to strengthen the safety management of the elevator, the strict implementation of special equipment safety technical specifications (hereinafter referred to as the safety technical specification), the use of safety is responsible for the elevator.
Units should use the purchase to meet the safety technical specification of the elevator, to ensure the inputs required for the safe operation of the elevator, it is strictly prohibited to purchase state explicitly eliminated products.
Article 5 units shall be according to the elevator safety technical specifications and product installation and maintenance instructions and the actual usage, tissue repair and maintenance.
Units should be commissioned to obtain the corresponding elevator maintenance project approval unit (hereinafter referred to as the maintenance unit) for maintenance, and maintenance units sign the maintenance contract, agreed in the maintenance period, their request and the rights and obligations. The maintenance contract at least include the following contents:
(a) the content and requirements of maintenance; (II) maintenance time frequency and time limit; (III) maintenance units and the use of units on both sides of the rights, obligations and responsibilities.
Article 6 units shall set up elevator safety management institution or equipped with elevator safety management personnel, at least a made "special equipment operating personnel certificate" the elevator safety management personnel assume corresponding management responsibilities.
Seventh units shall be used in accordance with the actual situation of the unit, the establishment of the core of the post responsibility system for the use and operation of the elevator safety management system, and strictly enforced. The safety management system includes at least the following:
(a) the responsibilities of the relevant personnel; (II) the rules for safe operation; (III) daily inspection system; maintenance system; (5) regular inspection system; (6) the elevator key use management system; (VII) homework personnel and relevant operational staff training and examination system; (8) to an accident or accident emergency rescue plans and emergency rescue drill system; and (9) safety technical archives management system.
Eighth the use of the elevator before or after 30 days of use, the use of the unit shall be located in the city of quality and technical supervision departments (hereinafter referred to as the registration authority) for the use of registration. The following information shall be provided for the use of registration:
(a) organization code certificate or elevator property owners (refer to individual have identity cards (1 Xerox); (II) the special equipment using the registration form "(in duplicate); (3) installation supervision inspection report; (4) use and maintenance units signed a maintenance contract (original); (5) the elevator safety management personnel, elevator driver {for in accordance with Article 9 (5) with the requirements of elevator driver} and the associated with the elevator special equipment operating personnel certificate; (6) safety management system directory.
Maintenance unit is changed, the unit shall be to the maintenance contract, within 30 days after the entry into force of the new contract to the original registration authority shall go through the formalities of modification, and elevator maintenance unit logo replaced.
Lift scrapped, the use of units should be within 30 days to the original use of the registration authority for cancellation procedures.
Lift out of the 1 or more years after the withdrawal of the 1 regular inspection date, the use of units should be within 30 days to the original use of the registration authority for withdrawal procedures, re enable, should handle the opening procedures.
Article ninth the use of units shall perform the following duties:
(One) to maintain the elevator emergency alarm device can be used at any time with the use of unit safety management agencies or on duty personnel to achieve effective contact
(Two) in the elevator car or the obvious position of the entrance and exit of the effective "safety inspection certificate" signs;
(Three) the use of the elevator safety precautions and warning signs placed in the passenger's easy attention to the significant position;
(Four) in a prominent position on the elevator marked using the name of the unit management, emergency telephone and maintenance unit and emergency repair, telephone complaints.
(Five) hospitals in patients with the use of the elevator directly to the tourist is faster than that of 2.5m/s passenger elevator, and the driver to operate the elevator, by the holder of the elevator operator;
(Six) make appear emergencies or accidents emergency measures and rescue plan, schools, kindergartens, airports, stations, hospitals, shopping malls, sports stadiums, literary performance venues, galleries, tourist attractions and other personnel intensive places use the elevator unit, at least a year into a rescue drills and other units can be according to the characteristics of the units and the use of elevators, the timely rescue drills.
(Seven) when the elevator is difficult to take measures to appease the passengers, the organization of the elevator maintenance personnel to implement the rescue;
(Eight) in the elevator failure or abnormal circumstances, the organization to conduct a comprehensive inspection, to eliminate the hidden dangers of the elevator accident, the parties can be re put into use
(Nine) elevator accident, according to the organization of the emergency rescue, emergency rescue, dangers and rescue, protect the scene of the accident, and immediately report to the location of the accident of special equipment safety supervision and management departments and other relevant departments;
(Ten) supervision and with the elevator installation, renovation and maintenance and maintenance work;
(Eleven) elevator safety management personnel and operating personnel to carry out elevator safety education and training;
(Twelve) in accordance with the requirements of the safety technical specifications, the use of new safety and energy saving technology in a timely manner, to use the elevator to carry out the necessary transformation or update, improve the safety and energy efficiency in the use of elevators.
Tenth units of the use of security management personnel shall perform the following duties:
(One) to carry out daily inspections of the elevator operation and record the daily use of the elevator;
(Two) to develop and implement a regular inspection plan for the lift;
(Three) check the elevator safety precautions and warning signs, to ensure complete and clear;
(Four) properly keep the elevator key and its safety warning sign;
(Five) to find the hidden dangers of the elevator operation to stop the use of the right to make the decision to stop using, and immediately report to the person in charge of the unit;
(Six) after receiving the fault alarm, immediately rushed to the scene, the organization of the elevator maintenance personnel to implement the rescue;
(Seven) the implementation of the supervision of maintenance and maintenance work of the elevator installation, renovation, maintenance records, maintenance units to confirm the signature.
Eleventh units should be used to establish the elevator safety technical files. The safety technical file includes at least the following:
(I) the special equipment use registration form "; (II) equipment and parts, safety protection device of product technical documents; (III) installation, renovation, major repairs the relevant documents and reports; and (IV) daily inspection and use of records, maintenance records, annual self inspection record or report, emergency rescue drill record; (IIV) installation, alteration and major maintenance supervision and inspection report, periodic inspection report; (VI) failure of equipment operation and accident record.
Daily inspection and use of records, maintenance records, annual self inspection record or report, emergency rescue drill records, regular inspection reports, the operation of equipment fault records kept for at least 2 years and other information should be stored for a long time.
When using the unit to change, it shall hand over to the security technical file.
Twelfth in the elevator with a regular annual inspection. The units shall, in accordance with the requirements of the safety technical specification, put forward regular inspection applications to the special equipment inspection and testing institutions within 1 months after the expiry of the validity period of the inspection as prescribed by the marks of the safety inspection. The elevator without regular inspection or inspection is not allowed to continue to use.
Thirteenth lift passengers should comply with the following requirements, the correct use of the elevator:
(One) comply with the requirements of the elevator safety precautions and warning signs;
(Two) do not express in the normal state of the elevator;
(Three) non security means to open the door of the elevator floor;
(Four) the parts and their ancillary facilities of the elevator without dismantling or breaking the elevator;
(Five) do not take more than the rated load of the elevator, the delivery of goods shall not be overloaded;
(Six) other acts that endanger the safe operation of the elevator or endanger the safety of others.
Following slightly
上一条:Elevator small common sense: the classification of the escalator | next:Trapped in the elevator do not force to escape |